使用 pg-upmap¶
从 Luminous v12.2.z 版起, OSDMap 里有一张新的 pg-upmap 例外表,以支持指定 PG 映射到指定的 OSD 。这样可以让集群可以更好地调整数据分布,在多数情况下,可以把 PG 完美地散布到各 OSD 上。
这个新机制的关键点是,它需要所有客户端都能理解 OSDMap 里新增的 pg-upmap 数据结构。
启用此功能¶
New clusters will have this module on by default. The cluster must only have luminous (and newer) clients. You can the turn the balancer off with:
ceph balancer off
To allow use of the feature on existing clusters, you must tell the cluster that it only needs to support luminous (and newer) clients with:
ceph osd set-require-min-compat-client luminous
This command will fail if any pre-luminous clients or daemons are connected to the monitors. You can see what client versions are in use with:
ceph features
均衡器模块¶
ceph-mgr 的 balancer 模块会自动均衡各 OSD 的 PG 数量。见
Balancer
离线优化¶
Upmap entries are updated with an offline optimizer built into osdmaptool.
Grab the latest copy of your osdmap:
ceph osd getmap -o om
Run the optimizer:
osdmaptool om --upmap out.txt [--upmap-pool <pool>] [--upmap-max <max-optimizations>] [--upmap-deviation <max-deviation>] [--upmap-active]
It is highly recommended that optimization be done for each pool individually, or for sets of similarly-utilized pools. You can specify the
--upmap-pooloption multiple times. “Similar pools” means pools that are mapped to the same devices and store the same kind of data (e.g., RBD image pools, yes; RGW index pool and RGW data pool, no).The
max-optimizationsvalue is the maximum number of upmap entries to identify in the run. The default is 10 like the ceph-mgr balancer module, but you should use a larger number if you are doing offline optimization. If it cannot find any additional changes to make it will stop early (i.e., when the pool distribution is perfect).The
max-deviationvalue defaults to 5. If an OSD PG count varies from the computed target number by less than or equal to this amount it will be considered perfect.The
--upmap-activeoption simulates the behavior of the active balancer in upmap mode. It keeps cycling until the OSDs are balanced and reports how many rounds and how long each round is taking. The elapsed time for rounds indicates the CPU load ceph-mgr will be consuming when it tries to compute the next optimization plan.Apply the changes:
source out.txt
The proposed changes are written to the output file
out.txtin the example above. These are normal ceph CLI commands that can be run to apply the changes to the cluster.
The above steps can be repeated as many times as necessary to achieve a perfect distribution of PGs for each set of pools.
You can see some (gory) details about what the tool is doing by
passing --debug-osd 10 and even more with --debug-crush 10
to osdmaptool.